中文 中文
Home/ Products/

Biological Purification Air Conditioning System Unit

Unit Biological Purification Air Conditioner
High System Integration

Integrates air purification, sanitization, temperature and humidity adjustment to both fresh air and exhaust air, this multi-function Unit requires shorter on-site installation time at lower cost.

Flexible Setting

Flexible setting to maintain the Indoor Positive or Negative air Pressure

Decentralized Independent System

The unique one system per room design minimizes the risk of cross contamination comparing with the Integral Full Air System

Excellent Bactericidal Efficiency

By using the combination of online electret technology and online in-situ regeneration technology, the purification efficiency of particulate matter aerosol reaches 99%, and the bactericidal rate is greater than 98%.

Special for Epidemic Prevention - Unit Biological Purification Air Conditioner

The unit type biological purification air conditioning system is highly integrated, which integrates the functions of fresh air, exhaust air, purification and elimination, temperature and humidity regulation in one. The distributed independent system can efficiently kill bacteria.

The novel coronavirus (2019-NCoV) can cause a variety of respiratory syndrome diseases and has the characteristics of easy mutation, strong infectivity and great harm. China has made major strategic achievements in epidemic prevention and control. While the epidemic has been carried out with regular and precise prevention and control, the development of the epidemic remains complex, with some cases occurring in some regions. In the normal epidemic prevention and control, strengthening support has always been a priority. In the medical and health system, the construction of nucleic acid testing capacity and negative pressure isolation facilities is of great significance.

On the one hand, people need to go through tedious steps to complete nucleic acid sampling in hospitals, and registration and sampling personnel need to wear protective clothing for a long time, which causes great physical and mental load on personnel. In addition, it is inconvenient to arrange relevant sampling areas in office buildings, railway stations, airports and other scenes, and it is difficult to quickly implement nucleic acid sampling.

On the other hand, in order to meet the needs of infectious disease prevention and control and outbreak, the construction of negative pressure isolation facilities is particularly important, especially in the county and township level medical institutions to build patient reception capacity, it is more necessary to provide a safe working environment for medical staff, to ensure that medical staff are not infected, indoor and outdoor environment is not polluted and no cross infection occurs.

Unit type biological purification air conditioning system

Unit biological purification air conditioning system is highly integrated, set fresh air, exhaust air, purification and elimination, temperature and humidity regulation and other functions in one, only rely on one equipment can achieve indoor positive/negative pressure air protection requirements, simple construction, low construction cost, can effectively prevent the invasion or leakage of bacteria, viruses.

01 Switch between positive pressure and negative pressure modes

Users can effectively reduce the risk of infection by switching between positive and negative pressure modes according to actual requirements.

02 Strong kill

Outdoor polluted air enters the room after filtration and elimination treatment by the protection unit; The pollutants in indoor air are forcefully killed by the biological inactivation unit before entering the outdoor to prevent the leakage of microbial pollution.

03 Positive and negative pressure intelligent maintenance

Integrated intelligent microcontroller, through intelligent matching of fresh air and exhaust air volume, automatically maintain the set positive or negative pressure.

04 Inner circulation purification system

The concentration of indoor particulate matter and microorganism was significantly reduced by internal circulation purification.

05 Temperature and Humidity Regulation

System built-in air conditioning terminal, single or multiple biological purification air conditioning terminal and the central air conditioning cold and heat source directly connected to achieve indoor temperature and humidity regulation.

06 Heat recovery heat transfer

Exhaust air and fresh air heat recovery, reduce energy consumption, energy saving and environmental protection.

07 Fresh air system

The outdoor air is sent indoors after efficient filtration and elimination.

Negative pressure ward application system scheme

The unit type biological purification air conditioning system is adopted. Each negative pressure ward is independently equipped with biological purification air conditioning terminal, which integrates the functions of fresh air, exhaust air, purification and elimination, temperature and humidity regulation, etc., to meet the requirements of air protection in the negative pressure ward, effectively prevent cross infection and meet the needs of comfort. Multiple negative pressure wards share heat and cold sources. The system has high integration, simple construction and low construction cost. The system operates in negative pressure mode by default. If necessary, you can switch to positive pressure mode with authorization.

Meeting room, office application system scheme

The use of unit biological purification air conditioning system, independent configuration of biological purification air conditioning end and heat and cold source, set fresh air, exhaust air, purification and elimination, temperature and humidity regulation functions in one, to meet the needs of indoor air protection. By default, the system runs at positive pressure. Users can switch to the negative pressure mode based on actual requirements to flexibly meet the requirements of positive and negative pressure protection and effectively reduce the risk of infection.

Application scenario


01 Negative pressure ward

The unit type biological air conditioning purification system is highly integrated, and only one device can meet the air protection requirements of negative pressure wards. Simple construction, low construction cost, integrated control, easy to use.

02 Negative pressure isolation room

Unit type biological purification air conditioning system is highly integrated, each negative pressure isolation ward can only rely on one equipment to achieve the air protection needs, all negative pressure wards can share cold and heat sources, simple construction, low construction cost, integrated control, easy to use.

03 VIP Room/High speed Rail VIP Channel

Set temperature control, efficient air purification, strong kill in one, positive and negative pressure adjustable for emergency conversion, the system can be directly connected with the central air conditioning host, high functional integration, easy to install, low cost.

04 Office

Indoor pressure can be separately controlled, adjusted to the positive pressure state, to prevent outdoor pollutants into the indoor; When it is adjusted to negative pressure, it can prevent indoor pollutants from leaking without treatment and reduce the risk of cross infection among office workers.

05 Moon Center

Through the indoor free conversion of positive and negative pressure state, to prevent the invasion of bacteria and viruses, to provide a clean, safe and comfortable air environment for infants and mothers with poor resistance in the maternity center.

name parameter
Rated circulating air volume 570m³/h
Fresh air volume 150m³/h
Filtration and purification efficiency >99.99%
Biological inactivation efficiency E. coli not less than 95% within 15min; Not lower than 80% in 90min of subtilis spore
Pressure range -50~50Pa
Rated power 150W(220V,AC)
Rated heat production 4685W
Rated refrigerating capacity 2928W
dimension 1498*998*334
weight 60kg
: